Leave Your Message

End-point Chromogenic Method for Bacterial Endotoxin Testing: Reliable Solutions from China Suppliers and Factory

,

End-point Chromogenic Method for Bacterial Endotoxin Testing (BET)
The End-point Chromogenic Method is a precise quantitative assay utilizing Limulus Amebocyte Lysate (LAL). This advanced technique allows for the detection of endotoxins by activating Factor C, which triggers an enzymatic cascade that cleaves a chromogenic substrate, leading to the release of a measurable chromophore. This product is not registered with the U.S. FDA and is intended for research use only within the U.S.
Procedure:

,
    ,
  1. Combine the test sample with LAL reagent and chromogenic substrate.
  2. ,
  3. Incubate the mixture at 37 ± 1 °C for a designated period, such as 60 minutes.
  4. ,
  5. Terminate the reaction with acid and measure the absorbance at 405 nm. Endotoxin levels are determined by comparing the absorbance of the sample against a standard curve established from known endotoxin concentrations. This method ensures high specificity and quantitative accuracy, making it a preferred choice for pharmaceutical and medical device testing. With a focus on providing high-quality testing solutions, our China suppliers and factory are committed to delivering reliable products for endotoxin testing.
  6. ,
,

    Catalog Number

    Catalog No. Description Specification and Configuration
    ECA40TA BETMAT™ EC Endotoxin Assay Kit
    (End-point Chromogenic Method), 40 Tests/Kit
    • 2 vials of LAL Reagent, 1.1ml/vial
    • 2 vials of LAL Reagent Water, 20ml/vial
    • 2 vials of Control Standard Endotoxin
    • 2 vials of Chromogenic Substrate, 2.2 ml/vial
    ECA40TB

    Frequently Asked Questions (FAQ)

    Q What detection method does the BETMAT™ EC Endotoxin Assay Kit use?

    The kit utilizes the End-point Chromogenic Method for the quantitative detection of endotoxins.

    Q How many tests can be performed with one BETMAT™ EC Endotoxin Assay Kit?

    Each kit is configured to perform 40 tests (40 Tests/Kit).

    Q What are the available catalog numbers for this assay kit?

    The kit is available under two catalog numbers: ECA40TA and ECA40TB.

    Q What components are included in the kit configuration?

    The kit contains 2 vials of LAL Reagent (1.1ml/vial), 2 vials of LAL Reagent Water (20ml/vial), 2 vials of Control Standard Endotoxin, and 2 vials of Chromogenic Substrate (2.2 ml/vial).

    Q What is the volume of LAL Reagent provided per vial?

    Each of the 2 provided vials of LAL Reagent contains a volume of 1.1ml.