End-point Chromogenic Method for Bacterial Endotoxin Testing: Reliable China Suppliers and Factory Solutions

End-point Chromogenic Method for Bacterial Endotoxin Testing (BET)
The End-point Chromogenic Method is a precise quantitative assay utilizing Limulus Amebocyte Lysate (LAL). This method involves endotoxin activating Factor C, which initiates an enzymatic cascade that cleaves a chromogenic substrate, resulting in the release of a measurable chromophore. Please note that this product is not registered with the U.S. FDA and is intended for research use only in the U.S.
Procedure:
  1. Combine the test sample with LAL reagent and chromogenic substrate.
  2. Incubate at 37 ± 1 °C for a specified duration (e.g., 60 min).
  3. Stop the reaction using acid and measure the absorbance at 405 nm. Endotoxin levels are ascertained by comparing the sample’s absorbance to a standard curve formulated from known endotoxin concentrations. This method offers high specificity and quantitative accuracy, making it a preferred choice in pharmaceutical and medical device testing. As a leading supplier in China, our factory is dedicated to providing high-quality testing solutions tailored for your needs.

    Catalog Number

    Catalog No. Description The kit Specification and Configuration
    ECA40TA BETMAT™ EC Endotoxin Assay Kit
    (End-point Chromogenic Method),
    40 Tests/Kit
    • 2 vials of LAL Reagent, 1.1ml/vial
    • 2 vials of LAL Reagent Water, 20ml/vial
    • 2 vials of Control Standard Endotoxin
    • 2 vials of Chromogenic Substrate, 2.2 ml/vial
    ECA40TB

    Frequently Asked Questions (FAQ)

    What is the detection method used in the BETMAT™ EC Endotoxin Assay Kit?

    The kit utilizes the End-point Chromogenic Method for the quantitative detection of Gram-negative bacterial endotoxins.

    How many tests can be performed with a single BETMAT™ EC Endotoxin Assay Kit?

    Each kit (Catalog No. ECA40TA and ECA40TB) contains sufficient reagents to perform up to 40 tests.

    What are the key components included in the kit configuration?

    The kit configuration includes 2 vials of LAL Reagent (1.1ml/vial), 2 vials of LAL Reagent Water (20ml/vial), 2 vials of Control Standard Endotoxin, and 2 vials of Chromogenic Substrate (2.2 ml/vial).

    What is the difference between Catalog Numbers ECA40TA and ECA40TB?

    Both catalog numbers represent the BETMAT™ EC Endotoxin Assay Kit with 40 tests per kit, sharing the same main components and specifications.

    Is LAL Reagent Water included in the kit?

    Yes, the kit contains 2 vials of LAL Reagent Water, with each vial containing 20ml.