End-point Chromogenic Method for Bacterial Endotoxin Testing (BET)
The End-point Chromogenic Method is a highly effective quantitative assay based on Limulus Amebocyte Lysate (LAL). This method utilizes the activation of Factor C by endotoxin, which initiates an enzymatic cascade that cleaves a chromogenic substrate, thereby releasing a measurable chromophore for accurate detection. This product is not registered with the U.S. FDA. For use in the U.S., it is intended for research purposes only.
Procedure:
Mix the test sample with LAL reagent and chromogenic substrate. Incubate at 37 ± 1 °C for a specified duration (e.g., 60 minutes). Stop the reaction with acid and measure the absorbance at 405 nm. Endotoxin levels are quantified by comparing the sample’s absorbance to a standard curve created from known endotoxin concentrations. This method offers high specificity and quantitative accuracy, making it a preferred choice among suppliers and manufacturers in the pharmaceutical and medical device sectors, especially in China. As a reliable factory for endotoxin testing solutions, we ensure the utmost quality and efficiency for your testing needs

    Catalog Number

    Catalog No. Description The kit Specification and Configuration
    ECA40TA BETMAT™ EC Endotoxin Assay Kit
    (End-point Chromogenic Method),
    40 Tests/Kit
    • 2 vials of LAL Reagent, 1.1ml/vial;
    • 2 vials of LAL Reagent Water, 20ml/vial;
    • 2 vials of Control Standard Endotoxin;
    • 2 vials of Chromogenic Substrate, 2.2 ml/vial;
    ECA40TB

    Frequently Asked Questions

    Q What is the detection method used in the BETMAT™ EC Endotoxin Assay Kit?
    The kit utilizes the End-point Chromogenic Method for the quantitative detection of endotoxins.
    Q What is the difference between Catalog No. ECA40TA and ECA40TB?
    Both catalog numbers refer to the BETMAT™ EC Endotoxin Assay Kit (End-point Chromogenic Method) with 40 Tests/Kit, sharing the same specifications and configurations.
    Q What components are included in the kit configuration?
    Each kit contains 2 vials of LAL Reagent (1.1ml/vial), 2 vials of LAL Reagent Water (20ml/vial), 2 vials of Control Standard Endotoxin, and 2 vials of Chromogenic Substrate (2.2 ml/vial).
    Q How many tests can be performed with one BETMAT™ EC Endotoxin Assay Kit?
    One kit is designed to support up to 40 tests.
    Q What is the purpose of the Control Standard Endotoxin in the kit?
    The Control Standard Endotoxin is used to prepare standard curves for quantification and to verify the assay's sensitivity and reliability.