Leave Your Message

China Suppliers Gel Clot Method LAL Reagent for BET Compliance - Endotoxin Detection from Factory

The Gel Clot method using Limulus Amebocyte Lysate (LAL) Reagent is an essential biological tool for detecting bacterial endotoxins, which are significant components of the outer membrane of Gram-negative bacteria and can cause severe pyrogenic reactions in humans. Sourced from the amebocyte lysate of horseshoe crabs (Limulus polyphemus and Tachypleus tridentatus), this reagent is integral to the coagulation cascade that responds to endotoxins, When the LAL Reagent is combined with samples such as pharmaceuticals, medical devices, or biological products at a controlled temperature of approximately 37°C, the endotoxins initiate a coagulation process that results in stable gel formation. A positive test result is indicated by the presence of a gel that maintains its structure when inverted, whereas a lack of gel signifies a negative result, Renowned for its high specificity, ease of use, and cost-effectiveness, the Gel Clot method is a critical component in pharmaceutical quality control and clinical diagnostics. It ensures that products are devoid of harmful endotoxins, thereby safeguarding patients from adverse reactions such as fever and sepsis. As a leading supplier of this essential reagent, our factory in China prioritizes quality and reliability for research purposes. Please note, this product is intended for research use only and is not registered with the U.S. FDA

    Catalog Number

    Catalog No. Sensitivity EU/ml ml/vial Tests/vial
    LAL015A 0.015 0.2 1
    LAL03A 0.03
    LAL06A 0.06
    LAL125A 0.125
    LAL25A 0.25
    LAL03B 0.03 2.2 20
    LAL06B 0.06
    LAL125B 0.125
    LAL25B 0.25
    LAL50B 0.5
    LAL03C 0.03 5.2 50
    LAL06C 0.06
    LAL125C 0.125
    LAL25C 0.25
    LAL50C 0.5

    Frequently Asked Questions

    What sensitivities are available for these LAL reagents?
    The LAL reagents are available in multiple sensitivities ranging from 0.015 EU/ml to 0.5 EU/ml (specifically 0.015, 0.03, 0.06, 0.125, 0.25, and 0.5 EU/ml) to accommodate various testing requirements.
    How many tests can be performed per vial?
    Depending on the selected catalog configuration, vials are packaged for 1 test (0.2 ml/vial), 20 tests (2.2 ml/vial), or 50 tests (5.2 ml/vial).
    How do I choose the correct Catalog Number for my application?
    You should select the Catalog Number based on your target sensitivity limit and your testing volume. For instance, suffix 'A' represents single-test vials (0.2 ml), suffix 'B' represents 20-test vials (2.2 ml), and suffix 'C' represents 50-test vials (5.2 ml).
    What does EU/ml stand for in the sensitivity column?
    EU/ml stands for Endotoxin Units per milliliter. It indicates the minimum concentration of endotoxin required to cause a gel clot reaction with the specific LAL reagent.
    Are these products suitable for gel-clot endotoxin testing?
    Yes, these configurations are specifically designed for the gel-clot method of LAL (Limulus Amebocyte Lysate) endotoxin testing, which remains a widely recognized reference standard.